DIAGNOSTIC SYSTEM FOR INDUCTION MOTOR STATOR WINDING FAULTS BASED ON AXIAL FLUX
 
More details
Hide details
1
Department of Electrical Machines, Drives and Measurements, Wroclaw University of Technology
 
2
Wroclaw University of Technology
 
 
Corresponding author
Marcin Wolkiewicz   

Department of Electrical Machines, Drives and Measurements, Wroclaw University of Technology, Smoluchowskiego 19, 50-372 Wrocław, Poland
 
 
Power Electronics and Drives 2017;2 (37)(2):137-150
 
KEYWORDS
TOPICS
ABSTRACT
The article presents the results of research on the use of an axial flux in the diagnostics of induction motor stator winding fed by a frequency converter. Voltage signal waveforms proportional to the axial flux were registered during motor operation in various conditions and were analysed with regard to the detection of stator winding short circuits. The taps of the selected coil turns of stator phases were introduced into the tested motor, which allowed to physically model inter-turn short circuits. The structure and the operation of the computer system used to monitor the state of induction motor windings were discussed. The developed diagnostic system was made in the Na-tional Instruments LabVIEW environment. The first part of the article is devoted to the issue of the analysis of the axial flux in the detection of induction motor stator winding faults. The second part presents the results of experimental research conducted using the developed diagnostic system.
eISSN:2543-4292
Journals System - logo
Scroll to top